Quantcast
Channel: OpenBuildings | AECOsim | Speedikon
Viewing all 34666 articles
Browse latest View live

Forum Post: End Type Connection in AECOsim Building Designer V8i SS5?

$
0
0
End Type Connection in AECOsim Building Designer V8i SS5 How many End Type Connection in Mechanical AECOsim Building Designer V8i SS5 ? how can i create my own end type connection with complected shape like Victaulic connection in the firefighting system? Victaulic Coupling

Forum Post: RE: Problems creating thumbnails

$
0
0
Joaquin, Where is the location of your catalog? Please let us know. Thank-you, Larry

Wiki Page: Is it possible to export Reality Mesh .3mx file type to .ifc file along with texture?

$
0
0
Product(s): AECOsim Building Designer Version(s): 08.11.09.866 Environment: N\A Area: Import/Export Subarea: Other Problem Is it possible to export Reality Mesh .3mx file type to .ifc file type by using IFC4 along with texture? It seems to be lost after export. Solution No, it seems that IFC4 class definition is not fully matured yet. Such as definition is now for triangulated faces only while more effective geometry are polygonal and constructive (CSG). So currently it is not possible to export graphics information from .3mx to .ifc is not possible in ABD.

Forum Post: RE: End Type Connection in AECOsim Building Designer V8i SS5?

$
0
0
Hi DMA, There are only two end types available in AECOsim. But there is a way to make your own custom components . You can create your own coupling and then place it in conjunction with other pipes and/or components with their individual end types as "-;-;". Please let me know if it helps. Satadal.

Forum Post: RE: End Type Connection in AECOsim Building Designer V8i SS5?

$
0
0
first of all thank you very much Satadal for your reply and for videos the shape of the output from video is very simple how can i define the complicated dimension for victaulic shape for example. if you have ready samples for complicated shape can you provide? regards

Forum Post: RE: End Type Connection in AECOsim Building Designer V8i SS5?

$
0
0
Hi DMA, Does this video help? (Please visit the site to view this video)

Forum Post: RE: End Type Connection in AECOsim Building Designer V8i SS5?

$
0
0
sure it is help But i need how can i define this complicated coupling shape in the cell model and connection point file. for example i have the cell shapes and i want use it automatically in the software!

Forum Post: RE: End Type Connection in AECOsim Building Designer V8i SS5?

$
0
0
If you can share the 3D model of this coupling, then I can show you how you can use this as a cell and define the connection points for this one. As an alternative, you can also share the appropriate 2D views with dimensions for me to create the 3D and then use it as cell with all the connection points. In case you want to go into deeper further discussion regarding this, you can raise a Service Request. We will communicate with you ASAP and work on your requirement.

Forum Post: RE: End Type Connection in AECOsim Building Designer V8i SS5?

$
0
0
[quote user="Satadal Dhar"]If you can share the 3D model of this coupling, then I can show you how you can use this as a cell and define the connection points for this one[/quote] (Please visit the site to view this file)

Forum Post: RE: End Type Connection in AECOsim Building Designer V8i SS5?

$
0
0
[quote user="Satadal Dhar"]As an alternative, you can also share the appropriate 2D views with dimensions for me to create the 3D and then use it as cell with all the connection points.[/quote] (Please visit the site to view this file)

Forum Post: RE: End Type Connection in AECOsim Building Designer V8i SS5?

$
0
0
[quote user="Satadal Dhar"]In case you want to go into deeper further discussion regarding this, you can raise a Service Request. We will communicate with you ASAP and work on your requirement.[/quote] yes sure i want go to the deep deeper. how can i raise a Service Request?

Forum Post: RE: DrawingSeed vs DesignSeed - whats the difference?

$
0
0
But there are also 2d Design models and they are used with OpenRoads technology where your 2d design elements are automatically converted into 3d in an auto-created 3d model in the same file. So a related question may be; What are the functionality difference between a 2d Design Model and a 2d Drawing model other than model properties being design vs. drawing and a black/design or grey/drawing background?

Forum Post: RE: End Type Connection in AECOsim Building Designer V8i SS5?

$
0
0
Hi DMA, Please check if following video addresses your requirement (Please visit the site to view this video)

Forum Post: RE: End Type Connection in AECOsim Building Designer V8i SS5?

$
0
0
To raise a Service Request, please visit this link and then login with your credentials. At the bottom of the page you will find the link to create a New Service Request.

Forum Post: Dialux icon not indicated in Lighting analysis menu bar

$
0
0
Dear Sir/Madam We are planning to do lighting calculation in dialux through aecosim, so we installed dialux in our PC, In ( PIC 01 )lighting analysis tool bar visual & relux only shown but in the list its shown dialux also, once i enable this three softwares ( PIC 02 )still Dialux is not shown in my tool bar and its not enable too PIC 01 PIC 02 Kindly suggest us the solution Thanks & regards M.KV Rajan +91 9585868707

Forum Post: RE: Datagroup Editing certified for use with ProjectWise ?

Forum Post: Datagroup Editing in Excel SS6+

$
0
0
Hey you DG-in-Excel fans, what happens when you export a value that is linked to or provided by something in Aecosim? For example: Doors and Spaces have dimensions / area values that are generated by the Aecosim tool. What happens when the user exports these values out into Excel and re-imports them? We seem to have lost the linkage between the door and spaces tools with their reported values or parameters. I am wondering if the Export to Excel tool has something to do with this.

Forum Post: RE: End Type Connection in AECOsim Building Designer V8i SS5?

Forum Post: RE: I can not place nodal Forces into my Model / Can't see nodes in the model.

$
0
0
Hi Nils, The member needs to be Analytical first in order to add the node. Later you can add Nodal Load:

Forum Post: RE: Datagroup Editing in Excel SS6+

$
0
0
This door dimension was edited in Excel and updated back into DataGroup Explorer using the Excel Exchange option. You can Edit in Excel and Update from Excel and the values should be linked back into the model. Is this the tool you used to edit the DataGroup property in SS6?
Viewing all 34666 articles
Browse latest View live