Forum Post: RE: Generating section information from imported I-models using...
FWIW, so, DEM does not support Type 106 elements which is what you will have in an i-model. For the fills, perhaps you can "layer" those where needed via a separate ref? Also hoping that others...
View ArticleForum Post: RE: Anyone exported to eff-be-ex files from ABD
I would recommend doing so if you can just to verify whether the issue still occurs. If the resulting file is 0KB it may be an issue outside of ABD itself.
View ArticleForum Post: RE: Slab Penetrations Tool- Problems with extractions
Are these mixed results in the same extraction?
View ArticleForum Post: RE: DV / hidden lines not printed
The attached zip file includes everything you need. The xml file should be put in the parts folder.
View ArticleForum Post: RE: IFC import / everything on default level
Just for the records, the reason for the behaviour is described here. communities.bentley.com/.../276850.aspx The ifc levels must not exist in a dgnlib file which is in the path of the MS_DGNLIBLIST...
View ArticleForum Post: RE: SS5 / VBA errors after installation of Structural...
SR 7000135775 filed.
View ArticleForum Post: RE: Slab Penetrations Tool- Problems with extractions
Nasir, Steve Thanks for responding to my post. The product is AECOsim Building Designer. I got the slab penetration tool to work by moving the feature slightly below slab level. This then forced the...
View ArticleForum Post: RE: Show/Hide Callouts
Hey, I may have missed the answer to this, if so apologies. I am trying to do something similar with Show/Hide callouts. I want to set my sheet seed to show markers as standard and should a marker not...
View ArticleForum Post: RE: Show/Hide Callouts
Version would help ... AECOsim Building Designer V8i (SS4) - Version 08.11.09.593 Thanks Daryl
View ArticleForum Post: RE: SS5 / VBA errors after installation of Structural...
Hi Andreas, Admin rights and UAC are different things. Please try reinstalling with UAC set to 'never notify'.
View ArticleForum Post: RE: SS5 / VBA errors after installation of Structural...
Please also see: communities.bentley.com/.../12957.aecosim-building-designer-installation-permissionssecurity.aspx
View ArticleForum Post: AECOsim Electrical files will not open
Posted for USACE user: AECOsim Electrical SS4 files will not open when the file is accessed through a Projectwise managed workspace. The dgn file can be checked out of Projectwise and downloaded to...
View ArticleForum Post: RE: Another Cut Solid by Curve Issue
The solids resolution is set to imperial while the units are metric as shown in the attached image, but I believe that's a non-factor because the core issue is a matter of resolution. The solid is...
View ArticleWiki Page: BXC Part Mapping Utility Error
Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.593 Environment: N/A Area: Utilities Subarea: Original Author: Robert DiMauro, Bentley Technical Support Group Problem...
View ArticleWiki Page: AECOsim Building Designer Installation - Permissions/Security
Applies To Product(s): AECOsim Building Designer V8i Version(s): 08.11.09.376 and above Environment: N/A Area: General Subarea: Original Author: Marc Thomas When installing AECOsim...
View ArticleWiki Page: AECOsim Building Designer Installation - Activating .NET Framework...
Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.735 Environment: Windows 8 Area: General Subarea: Installation Original Author: Steve Cocchi, Bentley Technical Support Group...
View ArticleForum Post: RE: ANZ Dataset
The first message is quite literal: by modifying elements in the current version of ABD, they may not be completely usable in previous versions due to schema or other dataset changes from version to...
View ArticleForum Post: RE: CUT PATTERNS - how do I make Cut Pattern align with a curved...
Can you first confirm the version you are using, dataset, and whether this is DV or DEM?
View ArticleForum Post: RE: CUT PATTERNS - how do I make Cut Pattern align with a curved...
Mojo, I am not sure a pattern is going to follow a curve as I think you are describing. (Steve might know a way) However, if you assign assign a batt insulation "linestyle" to centerline symbology it...
View Article