Wiki Page: BXC Part Mapping Utility Error

$
0
0
Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.593 Environment: N/A Area: Utilities Subarea: Original Author: Robert DiMauro, Bentley Technical Support Group             Problem Description When using the BXC Part Mapping utility, I get a vba runtime error message.  It seems to have something to do with the configuration variable ATFDIR_CELL or TFDIR_CELL.  If these variables only point to one folder, the vba works correctly; however, if this folder is appended to search multiple folders the vba fails.  Excel opens fine, but the error doesn’t occur until one tries to generate a BXC report. Steps to Resolve Replacing C:\ProgramData\Bentley\AECOsimBuildingDesigner V8i SS4\WorkSpace\BuildingDatasets\Dataset_US\macro\excel\BXCUtil.xltm file solves this issue since it may have been outdated. 