Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.735 and above Environment: N/A Area: Floor Management Subarea: Original Author: Marc Thomas, Bentley Technical Support Group This note is aimed at CAD/BIM Administrators only. Occasionally you may find 'orphaned' floors in a BB_Floormaster.dgnlib. They are visible if BB_Floormaster.dgnlib is opened directly but do not show up in Floor Manager and cannot be deleted by any of the usual methods. This is a short term issue that be dealt with by future improvements to the Floor Management system. In the meantime we have added a hidden key-in to AECOsim Building Designer SS5 that will delete all unassociated graphics from BB_FloorMaster.dgnlib when the Floor Manager dialog is open. Where ProjectWise is in use, it will checkin/out the dgnlib as well: In SS5 open the BB_Floormaster.dgnlib Open Floor Manager (this has to running for the elements in the BB_FloorMaster.dgnlib to be accessible to the command). Enter hidden command bb floor cleanup Close BB_Floormaster.dgnlib To avoid levels, line styles and other library elements being copied in to BB_Floormaster.dgnlib during this operation open the file using an administrator UCF containing the line BB_DVDATASETELEMENTS=0 as described in Managing dgnlib files .
↧