If I crash out of this stage of the installation, then run a repair, it finishes up and seem to run ok... not ideal though.
↧
Forum Post: RE: OBD Update 10.06.03.04 installer issue
↧
Forum Post: RE: Aecosim use in VR
Hi Mark, Interesting. What is the recommended workflow to create VR out of Aecosim model? Appreciate your help. Best Regards Mohammed Ansari BIM Consultant Saudi Arabia
↧
↧
Forum Post: RE: OBD Update 10.06.03.04 installer issue
Can confirm same behaviour, Happened when doing deployment, not actual installing. And happened during actual installing as well. After a while the installation dialog is just sitting there doing seemingly nothing:
↧
Wiki Page: Application Solutions - Facilities Space Planer
From the navigation bar on the left expand Application Solutions - Facilities Space Planer and select a solution.
↧
Forum Post: Link Drawing Title to Navigate Drawing and Sheet Models
AECOsim Building Designer SS6 ( Version - 08.11.09.866) Hi All, I have referenced a drawing model unto my sheet @ scale 1:100, using the "Place Drawing Title" tool, I have placed an unlinked drawing title on the titleblock. How do I create a link in this drawing title so that I can navigate the originating design and drawing models linked to the reference I have placed on my titleblock. the image below illustrate how I intend the drawing title to behave on prompt Thank you
↧
↧
Wiki Page: Manually placed DataGroup annotation is different than Drawing Rule based annotation
Product(s): OpenBuildings Designer and AECOsim Building Designer Version(s): CONNECT Edition Environment: N/A Area: Annotation Subarea: Drawing Rules Problem When I use the Element Annotation tool to manually annotate a Profile component it doesn't display the correct annotation cell, but when using drawing rule based annotation in the same drawing the results are correct. How is this possible? Solution The cell selected for Profiles in the Annotate Tool Settings dialog was set incorrectly resulting in unexpected graphics when manually annotating Profiles within the drawing. The Architectural Drawing Rule being used for Profiles, however, had the desired cell explicitly selected instead of using the Default Annotation Assignment cell which is why the Auto-Annotation results were correct.
↧
Forum Post: RE: Link Drawing Title to Navigate Drawing and Sheet Models
You can add your own links to an element through the Project Explorer . You can refer to the following article as an example: https://communities.bentley.com/products/microstation/w/microstation__wiki/35719/how-to-attach-several-links-from-file-to-elements-in-microstation
↧
Forum Post: Why the measure volume result is different between V8i version and CE version
Hi Dear all, I would like to ask the measurement question that I discover in these two versions. (AECOsim V8i SS6 and OpenBuildings CE 10050049en ) This situation is happened on my manager doing double-check the model volume. I was used AECOsim to create the model, then measure the volume. The result is 17146.2835m^3. However, when my manager used OBD to double-check, the result is different, is 17229.8567m^3. After that, I have test for a single element. the result is also different on the some element. as you can see in the picture below. Does anyone have some problem or anyone know what's happened on it?
↧
Forum Post: RE: Remove Instance Data
Hi Steven, I also have same question, when I try to your method is not work. I used ABD ss6. Do you have another method? Thanks.
↧
↧
Forum Post: RE: Remove Instance Data
I think this method is similar. https://communities.bentley.com/products/building/building_analysis___design/f/aecosim-speedikon-forum/141992/removing-part/430498#430498
↧
Forum Post: Cut pattern for timber stud to show X pattern
Hi I know the cut pattern can be set up in Family/part but I don't know how to make it show X pattern. For example as below picture Anyone can help?
↧
Forum Post: RE: Why the measure volume result is different between V8i version and CE version
Hi Lynn, Please share the file here. Thanks Regards, Arghyakamal
↧
Forum Post: RE: Properties Column Missing in Modify Element - ABD 593
Try to delete folder "prefs" in C:\Users\__"PCUser"__\AppData\Local\Bentley\AECOsimBuildingDesigner\8.11\QrHp_ibNA9yGRgjVZb6onA
↧
↧
Forum Post: RE: Cut pattern for timber stud to show X pattern
Wouldn't that X pattern (which is essentially 2 lines) be drawn in manually over the Dynamic view or reference the dynamic view into a compiled drawing and add what ever annotations and graphics you need. To expect to be able to scale a cut pattern so that it shows 1 X in exactly the right position without spill overs is asking a lot of the software.
↧
Forum Post: RE: Remove Instance Data
Wiki entry Also, I don't think that the MID tool works on nested objects. You will have to un-group or drop any Cells.
↧
Forum Post: RE: Floor manager
" But in your case the floormaster.dgnlib is not stored in a PW datasource nor managed by PW, correct? " That is correct. " I'm also assuming that your network folder pointed to by PROJ_DATASET is also being used by other variables... " I'm not sure what you're after here but I would say yes. " Do you see any other errors in the Message Center or is it only the floormaster? " Nothing of interest in the message center. " FWIW, using PW in a fully un-managed fashion is not something that we'd typically see or support. So it's possible that this may also be a factor. " Are you saying that using PW only as a repository for the files and having the workspace on local or network drive is not supported?
↧
Forum Post: Accusnap - Cannot snap to elements in forward view
Hi, I cannot snap to elements in the forward view when referencing a DV into a drawing model. The snap mode is on in the clip volume settings and my snaps are set to keypoint, midpoint intersection. I can snap to elements in the same DV that are being cut through. Any help appreciated. Sam ########## Solved Converted element to smart solid which has allowed me to snap on the element now. ##########
↧
↧
Forum Post: RE: Call out Not Creating Saved View or Drawing in Sheet Model
Hi Henry, You're welcome! Any chance you could upload that sheet file here with the referenced border? I'm not really sure why a callout isn't generated within the sheet boundary...
↧
Forum Post: SIG Virtual Workshop: OpenBuildings Designer - DataGroup Manangement
OpenBuildings Designer Special Interest Group: DataGroup Management Host: Paul Wagner, Content Engineer, Bentley Systems, Inc. 17 December 2019 at 11 a.m. EST or 100 p.m. EST Register Now It may be cooler outside, but December’s OpenBuildings Designer Special Interest Group virtual workshop has some hot topics that will keep you doing your best work. Enhance your OpenBuildings skills as we focus on DataGroup Management tools and capabilities: DataGroup Organization The Catalog Editor The Definition Editor Item Manager Custom Definitions Custom Catalog Types and Items This one-hour session is open to all Bentley users, includes a technology presentation, and provides time to share questions. See you online! Live, complimentary, and interactive – receive one PDH for your Bentley Transcript.
↧
Forum Post: RE: OBD Update 10.06.03.04 installer issue
QUESTION: I have noticed 10.06.03.04 show up on "application" for the CONNECTION Client. They it disappeared for two days. Now it's back. is it now SAVE to install this upgrade or should we wait. Is it OK to install it from the CONNECTION Client. Neal
↧