Forum Post: RE: DG values for HVAC/Plumbing elevations; Top, Bottom,...

Great, thanks Jeff.  Since the coding for drawing annotation and Flyovers are separate items we would need a CR for each.  Just include any detail regarding what you'd like see in the Flyover for the...

View Article


Forum Post: RE: Join with Elbow, Tee, Takeoff - What are the Key-in's? ABD 593

So far I  haven't been able to find the right syntax to enable the tool options.   However, you could record each one as a macro and then use those as key-ins instead.

View Article


Forum Post: RE: Mapping IFC and AECOsim Fields

FWIW, we are looking to remove those other property groups (tabs in Solibri) for the Ss5 release because you're right - they obviously are causing confusion! In regards to the Base Quantities tab, my...

View Article

Forum Post: RE: How to add a Step in an existing Building View?

Hi Chris, I've taken your SR and will link it to Enhancement 86193 for adding a Step after the Callout has been placed.

View Article

Forum Post: RE: Mapping IFC and AECOsim Fields

Steve, We're talking about two separate problems: 1/. Base Quantities does not always give figures (circular columns and feature cut objects often don't work) - Fix this and we'd be very happy!...

View Article


Forum Post: RE: Join with Elbow, Tee, Takeoff - What are the Key-in's? ABD 593

Excellent answer! I've known since V4 about macros, but never used them. Thanks!

View Article

Forum Post: RE: limitations of elevations in dynamic views

This looks to be the same topic as the post above: communities.bentley.com/.../67778.aspx

View Article

Forum Post: RE: Building Elements within Cells

A tree of nested references would be my approach also. Top level "assembly model" being the whole building- comprised of a series of referenced floor models (some of which hopefully repeat). Each...

View Article


Forum Post: RE: limitations of elevations in dynamic views

I think the solar analysis tool can produce vectorised shadow envelopes. You could use this as a basis to fake the shadows... Not sure if it works with clipped elements. Compositing: it would be good...

View Article


Forum Post: RE: Building Elements within Cells

Cells (Type 2) have been around since the beginning... apparently part of Mstn's basic file format which is based on ' linked list s'. I think this way of organising things can already be achieved...

View Article

Forum Post: RE: Mapping IFC and AECOsim Fields

Sorry, but I don't agree here. The problem with "burnt in" values is, that we can't trust them. If the geometry is calculated from the ifc model by the viewer, than it is possible to check it....

View Article

Forum Post: RFA import / structural connections

Question regarding RFA import of structural connections. I'm trying to import rfa files from Peikko, those are fastening plates. The RFA importer assigns them to discipline Architecture. I would like...

View Article

Forum Post: DV / hidden lines not printed

We're experiencing a problem when trying to print hidden lines from building views, they simply are not printed. SR 7000130301 filed.

View Article


Forum Post: RE: Rotation Views changing from defaults [V8i]

I'm not really following...  could you post a few screen captures to show what it is you're seeing?

View Article

Forum Post: RE: RFA import / structural connections

I'm struggling a bit to get it working, would be nice if you could have a look at the attachment. It includes a zipped folder with a rfa file and some xml definition files (don't know if they are...

View Article


Forum Post: RE: Drawing Models - Scale Issues

Note that this is the poblem also to the original note above with a miscale of 1:96 which is a scale of 1/8"

View Article

Forum Post: RE: Rotation Views changing from defaults [V8i]

Hopefully this makes it clearer. With my view rotation set to "Right-Isometric" it is display an Isometric view and in the second example it is displaying a right view as a front view. Thanks

View Article


Forum Post: RE: RFA import / structural connections

Adding your XSD and XML files to my workspace seem to cause the Wizard to hang at that spot but I don't see anything wrong with your files. I'll have the development team take a look and see if the...

View Article

Forum Post: RE: RFA import / structural connections

Thanks a lot, I appreciate that.

View Article

Forum Post: RE: I need help with labels

Balazs, are you using the DataGroup Annotation tool to manually tag each object in a Dynamic View? If so, first chose the tool, then select the section of duct or pipe. The tag should appear on your...