Forum Post: RE: clash detection
But that is not a viable solution as a mitered cut is proper for unification and centerlines.
View ArticleForum Post: RE: Part xml not valid but works
I use Notepad++, Microsoft XML Notepad is a popular XML specific tool.
View ArticleForum Post: RE: SS5 - Snaps are basically utterly useless when modelling
I have also experienced the same behavior with SS5, particularly Intersection Snap. This was not a problem with previous releases. Work around has been to overlay lines along the geometry to achieve...
View ArticleForum Post: RE: SS5 - Snaps are basically utterly useless when modelling
You say this is a 2d plan??? is this a DV? And are you working in a 3d file 2d file and is the DV live or referenced?
View ArticleForum Post: RE: Stairs
I'm wondering if there ever was a SR filed on this? I'm seeing the same problem with SS5. If there wasn't, then I'll file one.
View ArticleWiki Page: Unwanted Levels in AECOsim Building Designer DGN Files
Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.593 Environment: N/A Area: dgnlibs, levels, linestyles Subarea: Original Author: Marc Thomas, Bentley...
View ArticleForum Post: Why can't AECOsim work on large files?? - ABD SS5
Does anyone else have issues when trying to work on large files? I do industrial layouts which means I receive files from clients and vendors which can be fairly large (file size). These files are...
View ArticleWiki Page: Updating/Migrating and SS3 Datasets to SS4
Applies To Product(s): AECOsim Building Designer V8i Version(s): 08.11.09.593 Environment: N/A Area: Dataset Subarea: Migration/Utilities Original Author: Marc Thomas Assumptions: This...
View ArticleForum Post: RE: How many times a day does AECOsim crash for you?
I understand from a colleague that the I-models do contain a large amount of redundant data, therefore using up valuable resources. I would focus there first if you can, as that is likely to impact...
View ArticleForum Post: RE: Empty Forms and Building Dataset Elements -what are they?
Yes, that is what we call them. Literally because they're used to create levels from the dataset (Family + Part in this case). If you open the Compress options dialog you can uncheck everything but...
View ArticleWiki Page: Snap the corner of a beam or column
Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.747 Environment: N\A Area: Platform Tools Subarea: Snaps Original Author: Johannes Lerch, Bentley...
View ArticleForum Post: insulation hatch
regardign the insulation hatch " find the below image "who know how ican add to the insulation part in order to see it in the cut drawing , I found way for linear element " by generate center line...
View ArticleWiki Page: Export DWG and create elements in Drawing Space
Applies To Product(s): AECOsim Building Designer Version(s): 08.11.09.747 Environment: N/A Area: Platform Tools Subarea: DWG Original Author: Larry Abla, Bentley Technical...
View ArticleForum Post: RE: How many times a day does AECOsim crash for you?
Too many levels have NEVER caused my crashes. It is ugly but I bet the problems are elsewhere.
View ArticleForum Post: RE: insulation hatch
Another way is to define the centerline as insulation and define a scale. The fit to width does not work yet however. Some walls rely on the insul to tell the story and a fit insul like above does...
View ArticleForum Post: RE: Empty Forms and Building Dataset Elements -what are they?
That just prompts a question. Instead of loading the dataset when every file is open. Why not load the Company Dataset when ABD is opened and only append the project dataset? So for those of us that...
View Article