Forum Post: RE: How can i set different Drawing Symbology on a single element

$
0
0
Is the dashed line in the reflected ceiling plan being defined by Family and Part?   If so, using Level Manager check that the Level Override for that roof is set to Continuous (0) for the reference attachment, then in the Drawing's Reference Presentation dialog check on the Level Overrides option.   That should do it.